CCNA 1 - Module 4 Exam Version 3.1 Networking Basics

CCNA 1 - Module 4 Exam Version 3.1 Networking Basics

1. To ensure reliable LAN communications, what should a technician be looking for when attaching connectors to the ends of UTP cable?
• that the white-orange/orange pair is attached first
that the wire pairs remain twisted as much as possible
• that one end of the shield is properly ground but not the other
• that 50 ohm termination resistors are on both ends

2. What factors need to be considered to limit the amount of signal attenuation in Ethernet cable runs? (Choose two.)
• type of users
• number of users
length of cable
• type of electrical equipment
installation of connectors on the cable

3. How are binary ones and zeros represented in fiber optic installations? (Choose two.)
• +5 volts/-5 volts
• 0 volts/5 volts
light/no light
• high to low electrical transition
• low to high electrical transition
increasing/decreasing light intensity

4. Which of the following describes frequency?
• length of each wave
• height of each wave
number of cycles each second
• amount of time between each wave

5. A company needs to extend the LAN to six separate buildings. To limit the amount of signal attenuation on the LAN media, what type of media would be the best to use between the buildings?
• air (wireless)
• coaxial cable
fiber
• shielded twisted pair
• unshielded twisted pair

6. What is expected when crosstalk is present in networks with higher transmission frequencies? (Choose two.)
• jitter
increase in crosstalk
• higher signal attenuation
• increases in cancellation effect
destruction of more of the data signal

7. Which of the following are detected by the wire map test? (Choose three.)
• near-end crosstalk (NEXT)
opens
• propagation delay
• return loss
reversed-pair faults
short circuits

8. A small company is experiencing difficulties on its LAN. After performing some tests, a technician has determined that the copper media supporting the LAN is experiencing abnormal attenuation. What are two possible causes of the problem? (Choose two.)
defective connectors
excessively long cable lengths
• use of higher grade cabling
• low frequency signals used in the media
• network cable runs isolated from other cables

9. What is a cause of crosstalk in UTP cable?
• cable pairs that are shorted
• cable pairs crossed during termination
• cabling runs installed in separate conduit
cable pairs that are untwisted because of poor termination of the cable

10. What conditions are described when transmission signals from one wire pair affects another wire pair? (Choose two.)
noise
• resistance mismatch
• jitter
crosstalk
• attenuation